Part Number Hot Search : 
TG430 SC425 NR7500BP 30007 B82614 ST1394 571008 AK9240
Product Description
Full Text Search
 

To Download TFS190C Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 File:TFS190C.doc
Version 1.6
07.08.2002
VI TELEFILTER
Measurement condition
Ambient temperature TA: Input power level: Terminating impedance*: 23 0 input output
Filter specification
TFS 190 C
1/5
C dBm 610 // -10.4 pF 560 // -10,3 pF
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 190 C is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae.The nominal frequency fN is fixed at 190,0 MHz without tolerance. The values of the pass band ripple and the relative attenuation arel are guaranteed in the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the measurement tolerance scheme.
Data
Insertion loss (Reference level) Nominal frequency Pass band Relative attenuation fN fN fN fN fN + 2,0 5,0 12,0 5,0 ....
ae = amin
typ. value
8,2 dB
tolerance / limit
max 12 dB
fN
fN
190 2
MHz MHz
PB
arel
fN 2 MHz MHz ... fN 2,5 MHz MHz ... fN - 12 MHz MHz ... fN - 190 MHz ... fN + 12 MHz ... fN +270 MHz MHz MHz
1 36 40 36 45
dB dB dB dB dB
max max min min min min
2 5 32 36 32 36
dB dB dB dB dB dB
fN + 12,0
Phase variation fN 2,5 MHz Input power level Operating temperature range Storage temperature range Temperature coefficient of frequency
TCf**
1,2 -
rms
max max
4 10
rms dBm
- 30 C ... + 85 C - 55 C ... + 125 C -25 ppm/K -
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz)
generated: checked / approved:
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File:TFS190C.doc
Version 1.6
07.08.2002
VI TELEFILTER
(All dimensions in mm)
Filter specification
TFS 190 C
2/5
Construction, pin configuration and 50 - matching network
5.0 SQ 7 5
+0.15 -0.1
190 C P32
1 Date code
Pin 1 Pin 2 Pin 3 Pin 4 Output Ground Input Ground Pin 5 Pin 6 Pin 7 Pin 8 Input RF return Ground Output Ground date code: M N P ... year + week 2000 2001 2002
3
50 Ohm Test circuit
L1
3
1
L2
50 Ohm - 50 Ohm
Input, 50 Ohm
C1
SAW
5 7 L3
C2
Output, 50 Ohm
2,4,6,8
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File:TFS190C.doc
Version 1.6
07.08.2002
VI TELEFILTER
Stability Characteristics
Filter specification
TFS 190 C
3/5
After the following tests, the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4
Packing
Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 3000 min 300 mm min 500 mm min 300 mm
Tape (all dimensions in mm) W Po Do E : : : : 12 4 1,5 0,3 0,1 + 0,1
Do Po
EMBOSSED CARRIER TAPE
P2
1,75 0,1 5,5 0,05 0,75 2 8 1,5 5,3 5,3 0,1 0,1
P1
E
F : G (min) : P2 P1 Ao Bo : : : :
Ao
D1
CT
Bo
F
0,05 0,1
W
D1(min) :
G
CT
:
9,5
0,1
COVER TAPE
W2
Reel (all dimensions in mm): A : 330 12,4 + 0,2 18,4 50 13 0,2
A
C
N
W1 : W2 (max) : N (min) C : :
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File:TFS190C.doc
Version 1.6
07.08.2002
VI TELEFILTER
Air reflow temperature conditions
Filter specification
TFS 190 C
4/5
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File:TFS190C.doc
Version 1.6
07.08.2002
VI TELEFILTER
History
Version 1.0 1.1 1.2 1.3 1.4 1.5 1.6 Reason of Changes
Filter specification
TFS 190 C
5/5
Name Herrler Steiner Dr. Sabah Dr. Sabah Dr. Sabah Dr. Sabah Pfeiffer
Date 25.07.2001 20.09.2001 08.03.2002 15.03.2002 26.04.2002 29.05.2002 07.08.2002
Generation of specification according to customer requirements change of pinning according to customer proposal new Development specification Change of relative rejection and phase variation in pass band Add of rejection typical values Add of typical values and change to filter specification correct relative attenuation changing typical values of insertion loss, relative attenuation and temperature coefficient of frequency
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS190C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X